A two-week conversation with a European research lab — and what it taught us about specs, geometry, and saying the uncomfortable part early.
Not every good project ends in a purchase order. This one didn’t. We’re writing it up anyway, because the back-and-forth was a clean example of what custom magnet work actually looks like before anyone signs anything — and because the engineering was interesting enough to share.
The ask
A physics research group at a European university reached out about a pair of Halbach array rings. The plan: stack two of them vertically inside a vacuum chamber, mounted on a CF40 flange, about 5 mm apart, with both dipole fields pointing the same way. They needed a homogeneous field inside the bore for a quantum-metrology experiment — the kind of setup where field uniformity matters more than raw strength.
The starting envelope: outer diameter under 40 mm (35 mm would be ideal), and a height of “about 10 cm.”
Then 10 cm became 10 mm
Two emails in, that 10 cm turned out to be 10 mm. An honest slip — they caught it themselves — but a factor-of-ten difference in height completely changes what’s possible.
We only would have caught it anyway because we keep restating our understanding of the spec back to the customer before doing any real work. It feels almost too basic to mention, but a surprising number of magnet projects go sideways because someone read “cm” as “mm,” or assumed a tolerance nobody actually wrote down. Restating the spec is cheap insurance. We do it every time.
What field, and where?
The early target was “0.3–0.5 T.” Good number — but over what volume? A strong field at a single center point and a uniform field across a region are two very different design problems.
When we asked, the real requirement came out: a uniform field across a 5×5×5 mm cube at the center of the bore. That’s the spec. A target field strength with no region attached isn’t finished yet, and pretending otherwise just pushes the misunderstanding further down the line.
Where the geometry pushed back
This is where it got real. With the OD capped at 35–40 mm and only 10 mm of height, there’s very little room for magnet material — and the uniform-field region you can actually hold shrinks fast as you tighten the envelope.
So before quoting anything, we told them straight: with these constraints, holding a clean uniform cube would be difficult, and asked whether the ID (10 mm) and the height had any room to grow. They did. They relaxed the ID to roughly 5 mm minimum — higher if it improved uniformity — let the height grow as long as it still fit the chamber, and dropped the field target to a more forgiving 0.1–0.3 T. That’s a much healthier design space to work in.
The honest move here is to surface that tradeoff before the customer pays for a quote on something that won’t perform. Squeezing geometry to hit a size number while quietly missing the field spec helps nobody.
Their questions, our honest answers
A few of the questions they raised, and the short versions of what we told them:
- Are commercial NdFeB magnets okay in vacuum, or do they outgas? Generally fine for a setup like this with the right plating — nickel is standard and vacuum-friendly — assuming no high-temperature exposure. Plating and operating temperature are the two things to pin down.
- Can we bring the two arrays together by hand? Carefully, and above roughly 5000 Gs at the bore, we’d say no. Two same-direction Halbach rings that close together pull hard. The mounting has to control the approach and prevent rotation — that’s part of the design, not an afterthought.
- What field should we expect at this size? We had a similar array on file (OD 46, ID 16, 20 mm tall) that reached about 0.2–0.3 T at center. But that one was built for a multipole field, not a uniform one, so we flagged it as a rough reference only. Reusing an old number out of its original context is an easy way to mislead everyone, yourself included.
How it ended
After we proposed targeting an ID of 10–15 mm and around 20 mm height, and offered to run a simulation to confirm the recommended dimensions, the lab came back: after internal discussion, they were taking a different approach and wouldn’t need the array for now. They thanked us for the responsiveness. We thanked them and left the door open.
No sale. Still a good use of two weeks.
Why write up a quote that didn’t close
Because this is the work. Custom magnet projects live or die in the pre-PO conversation — clarifying the real requirement, finding where physics and geometry fight each other, and being straight about it. Sometimes that process ends in an order. Sometimes it reshapes the customer’s plan entirely, which is what happened here. Either way, the useful part shows up long before anyone pays an invoice.
If you’re working on something with awkward constraints — a tight envelope, a uniform-field requirement, a vacuum or high-temperature environment, an assembly that’s hard to handle safely — that’s exactly the kind of conversation we like to have. Bring the messy version. We’ll help you figure out what’s actually buildable.
— Jonah